-
MF102
(0 reviews)Model MF102 Rating in KVA 2.0 KVA Switching Technology IGBT-PWM Input Voltage AC Single phase 160V – 260V 50Hz Output Voltage AC Single phase 230V +/-1% 50 Hz Warranty for UPS (Years) 2 Battery/Backup Bank Provided with Online UPS ( Hint: In case the UPS is supplied with battery, seller shall ensure compliance to the GST Rates as per recommendations made in the 45th Meeting of GST council dated 17th Sep 2021 ) With Battery Type of Battery (hint: NA in case Battery not provided) SMF-VRLA conforming to JISC:8702(Pt.I,II&III), Stationary Lead Acid Batteries (with tubular positive plates) in monobloc container conforming to IS:13369:1992 latest Backup time (Minutes) (hint: NA in case battery not provided) 60 Minutes Warranty for battery (Years) by Battery Manufucaturer/Brand hint: NA in case battery not provided 2 Inbuilt isolation transformer With Overall Efficiency (%) >/=90% with Inbuilt isolation transformer Overload limit 20% Overload for minimum 10 minute ,50% Overload for minimum 1 minute Accessories Rack for Batteries ,Cabling 6 meters ( input upto 3m and output upto 3m) Type of Design / Construction Floor Standing Battery Model Number NA Battery capacity (Ah) 84 Weight of the Battery (kg) 28 Number of Batteries 4 Minimum Guaranteed VAH 1600 X Per KVA X Per hour of backup time Metering Input Voltage, Output Voltage Type of Design / Construction Floor Standing Enclosure (mm) 1.2 mm Minimum Thickness of M.S. Sheet duly powder coated Degree of Protection IP21 DC Bus Voltage (In Volts) 48 -
MF1101L
(0 reviews)Model MF1101L Rating in KVA 1.0 KVA Switching Technology IGBT-PWM Input Voltage AC Single phase160V – 260V 50Hz Output Voltage AC Single phase230V +/-1% 50 Hz Warranty for UPS (Years) 2 Battery/Backup Bank Providedwith Online UPS ( Hint: In case theUPS is supplied with battery, sellershall ensure compliance to the GSTRates as per recommendationsmade in the 45th Meeting of GSTcouncil dated 17th Sep 2021 ) With Battery Type of Battery (hint: NA in caseBattery not provided) SMF-VRLAconforming toJISC:8702(Pt.I,II&III),Stationary LeadAcid Batteries (withtubular positiveplates) inmonobloccontainerconforming toIS:13369:1992latest Backup time (Minutes) (hint: NA incase battery not provided) 30 Minutes Warranty for battery (Years) byBattery Manufucaturer/Brand hint:NA in case battery not provided 2 Inbuilt isolation transformer Without Overall Efficiency (%) >/=90% & <94%without Inbuiltisolationtransformer Overload limit 20% Overload forminimum 5 minute,50% Overload forminimum 3seconds Accessories Rack for Batteries,Cabling 6 meters (input upto 3m andoutput upto 3m),Paralleling kit forsynchronizing(ParallelRedundant LoadSharingConfiguration) Type of Design / Construction Floor Standing Battery Model Number NA Battery capacity (Ah) 26 Weight of the Battery (kg) 8 Number of Batteries 3 Minimum Guaranteed VAH 1600 X Per KVA X Per hour of backup time Type of Design / Construction Floor Standing Form factor of UPS NA (for Floor Standing) Enclosure (mm) 1.2 mm Minimum Thickness of M.S. Sheet dulypowder coated Degree of Protection IP21 DC Bus Voltage (In Volts) 36 -
MF1101L3
(0 reviews)Model MF1101L3 Rating in KVA 1.0 KVA Switching Technology IGBT-PWM Input Voltage AC Single phase 160V – 260V 50Hz Output Voltage AC Single phase 230V +/-1% 50 Hz Warranty for UPS (Years) 3 Battery/Backup Bank Provided with Online UPS ( Hint: In case the UPS is supplied with battery, seller shall ensure compliance to the GST Rates as per recommendations made in the 45th Meeting of GST council dated 17th Sep 2021 ) With Battery Type of Battery (hint: NA in case Battery not provided) SMF-VRLA conforming to JISC:8702(Pt.I,II&III), Stationary Lead Acid Batteries (with tubular positive plates) in monobloc container conforming to IS:13369:1992 latest Backup time (Minutes) (hint: NA in case battery not provided) 15 Minutes Warranty for battery (Years) by Battery Manufucaturer/Brand hint: NA in case battery not provided 2 Inbuilt isolation transformer Without Overall Efficiency (%) >/=90% & <94% without Inbuilt isolation transformer Overload limit 20% Overload for minimum 5 minute Accessories Rack for Batteries ,Cabling 6 meters ( input upto 3m and output upto 3m) Type of Design / Construction Floor Standing Battery Model Number NA Battery capacity (Ah) 12 Weight of the Battery (kg) 4 Number of Batteries 3 Minimum Guaranteed VAH 1600 X Per KVA X Per hour of backup time After sales service ( Turn Around Time) Within 48 hours Other Services provided PAN India service support on 24 x 7 basi Inbuilt isolation transformer Without As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes (For UPS rating upto 10KVA) -
MF1102L4
(0 reviews)Model MF1102L4 Rating in KVA 2.0 KVA Switching Technology IGBT-PWM Input Voltage AC Single phase 160V – 260V 50Hz Output Voltage AC Single phase 230V +/-1% 50 Hz Warranty for UPS (Years) 2 Battery/Backup Bank Provided with Online UPS ( Hint: In case the UPS is supplied with battery, seller shall ensure compliance to the GST Rates as per recommendations made in the 45th Meeting of GST council dated 17th Sep 2021 )With Battery With Battery Type of Battery (hint: NA in case Battery not provided) SMF-VRLA conforming to JISC:8702(Pt.I,II&III), Stationary Lead Acid Batteries (with tubular positive plates) in monobloc container conforming to IS:13369:1992 latest Backup time (Minutes) (hint: NA in case battery not provided) 120 Minutes Warranty for battery (Years) by Battery Manufucaturer/Brand hint: NA in case battery not provided 2 Inbuilt isolation transformer Without Overall Efficiency (%) >/=90% & <94% without Inbuilt isolation transformer Overload limit 20% Overload for minimum 5 minute ,50% Overload for minimum 3 seconds Accessories Rack for Batteries ,Cabling 6 meters ( input upto 3m and output upto 3m) Type of Design / Construction Floor Standing Battery Model Number NA Battery capacity (Ah) 130 Weight of the Battery (kg) 43 Number of Batteries 4 Minimum Guaranteed VAH 1600 X Per KVA X Per hour of backup time After sales service ( Turn Around Time) Within 48 hours Other Services provided PAN India service support on 24 x 7 basis Inbuilt isolation transformer Without Metering Input Voltage,Output Voltage,Input Frequency,Output Frequency Alarms and Indications Alarm for Low Battery,Indicator for Mains presence Additional Features Pure Sinewave AC Output As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes (For UPS rating upto 10KVA) -
MF1103
(0 reviews)Model MF1103 Rating in KVA 3.0 KVA Switching Technology IGBT-PWM Input Voltage AC Single phase160V – 260V 50Hz Output Voltage AC Single phase230V +/-1% 50 Hz Warranty for UPS (Years) 2 Battery/Backup Bank Providedwith Online UPS ( Hint: In case theUPS is supplied with battery, sellershall ensure compliance to the GSTRates as per recommendationsmade in the 45th Meeting of GSTcouncil dated 17th Sep 2021 ) With Battery Type of Battery (hint: NA in caseBattery not provided) SMF-VRLAconforming toJISC:8702(Pt.I,II&III),Stationary LeadAcid Batteries (withtubular positiveplates) inmonobloccontainerconforming toIS:13369:1992latest Backup time (Minutes) (hint: NA incase battery not provided) 90 Minutes Warranty for battery (Years) byBattery Manufucaturer/Brand hint:NA in case battery not provided 2 Inbuilt isolation transformer Without Overall Efficiency (%) >/=90% & <94%without Inbuiltisolationtransformer Overload limit 20% Overload forminimum 5 minute,50% Overload forminimum 3seconds Accessories Cabling 6 meters (input upto 3m andoutput upto 3m),NA Type of Design / Construction Floor Standing Backup time (Minutes) (hint: NA in case battery notprovided) 90 Minutes Battery Make 247PWR / After sales service ( Turn Around Time) Within 48 hours Battery Model Number NA Battery capacity (Ah) 84 Weight of the Battery (kg) 21 Number of Batteries 6